Banner
 
Spacer
icon
ArrowProduct Info
ArrowT-Module

 

 
  About the VPII-T Module
 

The T-Module is designed to enable VPII S Mode 3 to be directly interfaced to the TCP/IP network. Its basic operation is to convert data from RS232 to TCP/IP and vice versa. All data for TCP?IP communication is encrypted by AES ( Advanced Encryption Standard) for secure communication in the public network.

The VPII-T module provides easy implementation of central server system when designing access control and/or time attendance application using VPII-S Mode 3 hand vascular pattern verification terminal. The central server system can be a PC or a server computer or an embedded system designed for the purpose of access control.

The T-Module also has door lock control functions in order for the server system o implement a complete access control system without using additional devices. Moreover, the T-Module is capable of storing a limited amount of user data so that the user can access the system even if the server system is shut don or the communication function of the TCP?IP network in in trouble (Sage Mode Operation). The T-Module can refer to a maximum of 2 server systems, one of which can serve as a backup.

Configuration

 
  Hardware Specifications
 
Item
Description
Power
Operating power supply AC 100~250 V,50Hz/60Hz
Power consumption 18[W]
(DC 12[v] 1.5 [A])
No. of users
Normal Mode Depends on the server system
Safe Mode 100 users (Designed users + cached users)
Event memory
(safe mode)
Verification event
storage/queue
Up to 1000 events of verification
System log storage Up to 1000 system logs
Time zone control
Index table used Holiday table- 12 indexes
Time zone table- 12 indexes
External interface
RS-232 VPII-S (9,600 bps, 19,200 bps)
TCP/IP Server system
Door output Relay output (max. DC 12V, 1A)
Exit button Exit button input
Door sensor Door sensor input
Alarm Alarm Output (DC 12V, 400 ~500mA)
Operating Environment
Temperature -5 degrees celsius to 50 degrees celsius
Humidity 10% to 90%
 
  Main Functions
 

TCP/IP Interface

  1. Data conversion between RS232 and TCP/IP
  2. IP Address

Door control

1. Electrical lock connection

  • Relay output for door open
  • Time adjustment of relay output

2. Input port for exit button

3. Input port for door sensor to detech door status (open/close)

4. Alarm functions

  • Output port alarm unit connection (12V, 400 mA)
  • If the T-Module deteces door open when it does not output the door-open signal, it generates a signal on the alarm output port
  • It is possible to control the output time

Door Control Functions

 
 

 

 